SERVICESCONTACT US
        + 400-676-1966
      • ENRU
      • 三
      • Home Company Products
          Gas Pollution Source Online Monitoring/Контроль промышленных выбросов
          Flue Gas Analyzer/Газоанализатор дымовых газовCEMS/Система автоматического контроля выбросовOn-site Online Monitoring System(UVDOAS)/Система автоматического контроля выбросовVOCs Analyzer & System (FID)/Газовый хроматограф ЛОСVOCs Online Monitoring System (PID)/Система измерения концентрации ЛОСFTIR Analyzer & System/Газоанализатор дымовых газов многокомпонентныйTemperature, Pressure & Velocity Monitor/Измеритель скорости потокаDust monitor/Анализатор пылиHumidity Analyzer/Измеритель влажности
          Air Quality Monitoring & Park Monitoring/Контроль атмосферного воздуха
          Air Quality Monitoring System/Система непрерывного контроля качества воздухаDynamic Calibrator/Генератор газовых смесейZero Gas Generator/Генератор нулевого воздухаMicro Air Monitoring System/Система сигнализации загрязнения атмосферного воздухаAtmospheric Particulate Matter Monitor(β ray)/Анализатор пылиAmbient Dust Monitor(Laser Scattering)/Система контроля запыленности атмосферного воздухаAmbient VOCs Analyzer/воздуха Газовый хроматограф ЛОСEnrichment Analyzer/Блок термодесорбцииOpen-Path FTIR Gas Analyzer/Газоанализатор многокомпонентный
          Water Quality & Waste Water Monitoring/Контроль качества воды
          Water Quality & Waste Water Analyzer/Анализатор качества воды Sensor/ДатчикIntelligent Constant-Temperature Water Sampler/Блок отбора пробы термостатируемый
          Process Analysis and Safety/Контроль технологических процессов
          In-situ Laser Gas Analyzer/Газоанализатор дымовых газовExtractive Laser Gas Analyzer/Газоанализатор дымовых газовOn-site Online Monitoring System(TDLAS)/Система автоматического контроля выбросовHydrogen Analyzer/анализатор водородаCalorific Value Analyzer/Анализатор теплотворной
          Portable/портатитвный
          Portable Flue Gas Analyzer/Газоанализатор дымовых газов портативныйPortable FTIR Gas Analyzer/Газоанализатор дымовых газов многокомпонентный портатитвныйPortable VOCs Gas Analyzer/Газовый хроматограф ЛОС портативныйPortable Laser Gas Analyzer/Газоанализатор дымовых газов портативный
          Analysis Module/модуль анализа
          UVDOAS Analysis Module/модуль анализаTDLAS Analysis Module/модуль анализа
          Spare Parts/запасные части
          Spare Parts/запасные части
        Application News
          Industry News
          Company News
        Downloads Contact Us
    • >Products > EQMS-200 VOCs Online Monitoring System
      • EQMS-200 VOCs Online Monitoring System
      • Product Overview
      • MessageEmail

        EQMS-200 VOCs Pollution Source Online Monitoring System adopts Photo Ionization Detection Method (PID) for gas detection. It uses ultraviolet light produced by ion lamp to irradiate the target gas and the target gas will be ionized after absorbing enough ultraviolet light. The concentration of the target gas can be detected by measuring the tiny current produced after gas ionization.

        • Features

        • IP65 protective design of high standard, can be installed indoors or outdoors

          Auto zeroing and auto calibration design, reduces work load of maintenance greatly

          Modular design, low maintenance cost

          Auto temperature and pressure compensation, accurately calculate gas concentration under normal pressure

          Battery module can be equipped for continuous monitoring when power out

        • Applications

        •         Applied in various VOCs emission occasions including transportation equipment manufacturing, industrial coating, package printing, coating manufacturing, organic chemical industry, tire manufacturing, semiconductor integrated circuit industry, furniture manufacturing, electric wire, paint spraying & dry cleaning, shoemaking, synthetic material, etc.

        • Specifications

        • Measurement principle: PID

          Measuring gas: benzene, xylene, naphthalene, octane, ethylene,

          cyclohexane, acetone, propanal, ethers, etc.

          Range: 0~50ppm (customizable)

          Measuring error: ≤5%F.S.

          Response time: <5s (T90)

          Installation method: Wall-mounted or cabinet type

          Communication interface: RS232/RS485/GPRS

          Communication protocol: HJ/T 212, Modbus

          Output distance: The max wire transmission distance 2000m (RS485 mode)

          Working temperature: -25℃~55℃

          Power: AC220V, 50~60Hz, 200W

      • You May Also Like
      • AM-5200 NOx Analyzer

        EQMS-200 VOCs Online Monitoring System

        GSP-100 Sampling Probe (Conventional)

        GCOM-3000 VOCs Online Monitoring System

    • Products Gas Pollution Source Online Monitoring/Контроль промышленных выбросов Air Quality Monitoring & Park Monitoring/Контроль атмосферного воздуха Water Quality & Waste Water Monitoring/Контроль качества воды Process Analysis and Safety/Контроль технологических процессов Portable/портатитвный Analysis Module/модуль анализа Spare Parts/запасные части
    • News Industry News Company News
    • Home Company Application Downloads
    • Contact Us Tel : +400-676-1966E-mail : export@zetian-tech.comAdd : No. 22 Zhiren Street, Binjiang District, Hangzhou, Zhejiang, China.
    • © 2002-2022 HangZhou Chunlai Technology Co.,Ltd. All rights reserved.
    XSubmit success!