In the blast furnace smelting process, blast furnace gas is the emission gas from top stack through dedusting, filtering and purging. As a byproduct material in the blast furnace process, blast furnace gas is flammable and explosive. Therefore, on line monitoring system is required in the production process to ensure the production safety.
NO. | Measurement point | Temperature | Pressure | Measurement components | Detection purpose | Recommend products* |
1 |
Bag dedusting down stream |
200°C | 0.2MPa |
CO, Co2, O2, CH41 ,h2
|
Safety monitoring combustion, control hydrogen analyzer |
LGT-100 Hydrogen analyzer |
2 | Hot-air pipe line | 200-400°C | / | O2 | Monitoring O2 concentration of main pipe, adjust production devices, realize production optimization | LGT-100 |
3 | Hot-air stove exhaust gas | 200-400°C | Minute positive gas | co、02 | Control combustion efficiency | LGT-100 |
4 | Emission stack | / | / | NOX, SO2 etc. | Online monitoring concentration of exhaust gas | EM-5 |