Waste incineration plant shall automatically and continuously monitor the content of main components in the incineration flue gas, including CO, HF, HCl, SO2, NOX, flue gas, etc. Among them, HCl and HF are the difficulties of detection. Under this working condition, our company has launched the HCl/HF analysis system for waste incineration. Based on the principle of TDLAS, this system adopts Multi-channel Reflection Technology to increase the measuring optical path, and simultaneously measures HCl and HF by in-situ high temperature heat wet extraction method
Features
Extraction with overall high-temperature (above 120℃) tracing, avoiding HCl/HF dissolving in water and form sour corrosion.
On-site installation, avoiding the absorption of HCl and HF gas in the pipeline as far as possible to improve the measurement accuracy.
Adopt advanced online HCl and HF analysis technology "TDLAS Multi-channel reflection technology".
No moving parts, powerful functions, support auto calibration, remote operation and maintenance, remote software upgrade, etc.
Application
Suitable for various environmental protection and industrial process gas emission monitoring, mainly used for flue gas analysis in waste incineration plants.
Specifications
Range: 0~50ppm (lower range can be customized).
Detection limit: 0.5ppm
Zero drift: ≤1%F.S./7d
Span drift: ≤1%F.S./7d
Response time: ≤120s (T90).
External output interface: 4x4-20mA output,8xSwitch output.,
Communication interface: RS485/GPRS
Working temperature: -10℃~50℃