HM-100(Ⅱ) Heat Tracing Hygronom takes microprocessor as the core and high-temperature resistance temperature & humidity sensor as measuring unit. It is equipped with multiple signal output method including 4-20mA, RS232, RS485, etc. The product can be integrated in CEMS, which is installed at outlet of sampling tracing pipeline to measure humidity of flue gas during sampling process and transmit data to IPC via RS232.
Features
Imported high-temperature temperature & humidity sensor with CE certificate; accurate and stable measurement
With temperature compensation, temperature change has little influence on humidity, high measurement linearity
Various output methods are available, widely applied in different sites
Built-in high precision filter, no dust interference
Adjust purge frequency based on working condition, preventing gas path from blocking
Applications
It is suitable for humidity measurement of flue gas discharged by pollution source, based on which, converts wet flue gas concentration into dry flue gas concentration. It can be widely applied to online humidity monitoring in industry.
Specifications
Humidity range: 0~40% (VOL), 0~100% (VOL)
Humidity accuracy: ≤1.5%RH (5~95%RH)
Humidity stability: ≤1%RH/year
Response time: ≤10s (T90)
Supply voltage: 24VDC
Output signal: 4-20mA/RS232/RS485
Working temperature: -30℃~150℃
Working humidity: 0~100%RH
IP grade: IP65
Material: stainless steel
Probe dimension: L=145mm, Φ52mm